EasyManua.ls Logo

Siemens SINAMICS G120 - Fig. 3-137 7017 - DC braking (ASM, p0300 = 1)

Siemens SINAMICS G120
924 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SINAMICS G120 Control Units CU240B-2/CU240E-2
List Manual (LH11), 01/2016, A5E33839529
713
3 Function diagrams
3.16 Technology functions
Fig. 3-137 7017 – DC braking (ASM, p0300 = 1)
- 7017 -
Function diagram
87654321
fp_7017_97_51.vsd
Technology functions
G120 CU240B/E-2
09.12.2015 V4.7.6
DC braking (ASM, p0300 = 1)
MIN
[6714]
Kp Tn
p0347
p1234
p1233
p1232
p0347
p1232
<1> <2>
0
4
t
t
t
t
OFF
p1231 = 5 (OFF1/OFF3)
Pulse suppression
Pulse suppression
n_act
n_set
|I_set|
n_act
n_set
Braking response
|I_set|
The DC braking current is determined during automatic calculation (p0340 = 1).
The de-magnetization time is determined during automatic calculation (p0340 = 1, 3).
To pulse inhibit
To sequence control
From I²t control [8021]
|I_set|
Current actual values
The parameters of the
I_max current controller are also used.
To control [6730]
To U/f characteristic
[6301]
(0)
DCBRK Akt
p1230 [C]
DCBRK config
0 ... 14
p1231 [D] (0)
DCBRK I_brake
0.00 ... 10000.00 [Arms]
p1232 [D] (0.00)
DCBRK time
0.0 ... 3600.0 [s]
p1233 [D] (1.0)
DCBRK n_start
0.00 ... 210000.00 [rpm]
p1234 [D] (210000.00)
DCBRK ZSW
r1239
r1239
.10
DCBRK ZSW
r1239
r1239
.8
I_max_U_ctrl Kp
0.000 ... 100000.000
p1345 [D] (0.000)
I_max_U_ctrl Tn
0.000 ... 50.000 [s]
p1346 [D] (0.030)
r0072
U_output [Vrms]
r0068[0..1]
I_act abs val [Arms]
I_ctrl Kp
0.000 ... 100000.000
p1715 [D] (0.000)
I_ctrl Tn
0.00 ... 1000.00 [ms]
p1717 [D] (2.00)
Mot t_de-excitat
0.000 ... 20.000 [s]
p0347 [D] (0.000)
14
To pulse inhibit
To sequence control
To pulse inhibit
To sequence control
p1233
p1232
p0347
t
t
Pulse suppression
n_act
n_set
|I_set|
|I_act|
DC brake fault response
p1231 = 4 (control command)
DC braking when starting speed for DC braking (p1234) is fallen below.
DCBRK ZSW
r1239
r1239
DCBRK ZSW
r1239
r1239
DCBRK ZSW
r1239
r1239
<3>
p1234
1 = DC braking active
1 = DC braking ready
[2511.1]
|I_act|
|I_act|
<3>
<2>
<1>

Table of Contents

Other manuals for Siemens SINAMICS G120