2 Parameters
2.2 List of parameters
SINAMICS G120 Control Units CU240B-2/CU240E-2
474 List Manual (LH11), 01/2016, A5E33839529
6: Run-time group 6
9999: Do not calculate
Description: Setting parameter for the run sequence of instance NOT 2 within the run-time group set in p20088.
Note: The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description: Sets the signal source of input quantity I of instance NOT 3 of the inverter.
Description: Display parameter for the inverted output of instance NOT 3 of the inverter.
Description: Setting parameter for the run-time group in which the instance NOT 3 of the inverter is to be called.
Value: 1: Run-time group 1
2: Run-time group 2
3: Run-time group 3
4: Run-time group 4
5: Run-time group 5
6: Run-time group 6
9999: Do not calculate
Description: Setting parameter for the run sequence of instance NOT 3 within the run-time group set in p20092.
Note: The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
p20089 NOT 2 run sequence / NOT 2 RunSeq
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7216
Min Max Factory setting
0 32000 180
p20090 BI: NOT 3 input I / NOT 3 input I
Access level: 3 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7216
Min Max Factory setting
- - 0
r20091 BO: NOT 3 inverted output / NOT 3 inv output
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7216
Min Max Factory setting
- - -
p20092 NOT 3 run-time group / NOT 3 RTG
Access level: 3 Calculated: - Data type: Integer16
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7216
Min Max Factory setting
1 9999 9999
p20093 NOT 3 run sequence / NOT 3 RunSeq
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7216
Min Max Factory setting
0 32000 190

Table of Contents

Other manuals for Siemens SINAMICS G120

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS G120 and is the answer not in the manual?

Siemens SINAMICS G120 Specifications

General IconGeneral
Power Range0.37 kW to 250 kW
Output Voltage0 V to Input Voltage
Frequency Range0 Hz to 650 Hz
Enclosure RatingIP20, IP21, IP55
Control ModesV/f control, vector control, servo control
Protection FeaturesOvervoltage, undervoltage, short circuit
Communication InterfacesPROFIBUS, PROFINET, Modbus RTU
Operating Temperature-10°C to +50°C
Cooling MethodAir cooling
Input Voltage200 V to 240 V, 380 V to 480 V, 500 V to 690 V