Siemens SINAMICS G120 - p20219 BI: NSW 0 switch setting I; NSW 0 sw_setting; r20220 CO: NSW 0 output Y; NSW 0 output Y; p20221 NSW 0 run-time group; NSW 0 RTG; p20222 NSW 0 run sequence; NSW 0 RunSeq

Siemens SINAMICS G120
924 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SINAMICS G120 Control Units CU240B-2/CU240E-2
List Manual (LH11), 01/2016, A5E33839529
499
2 Parameters
2.2 List of parameters
Description: Sets the signal source of the switch setting I of instance NSW 0 of the numeric changeover switch.
Description: Display parameter for output quantity Y of instance NSW 0 of the numeric changeover switch.
Description: Setting parameter for the run-time group in which the instance NSW 0 of the numeric changeover switch is to be
called.
Value: 5: Run-time group 5
6: Run-time group 6
9999: Do not calculate
Description: Setting parameter for the run sequence of instance NSW 0 within the run-time group set in p20221.
Note: The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description: Sets the signal source of input quantities X0 and X1 of instance NSW 1 of the numeric changeover switch.
Index: [0] = Input X0
[1] = Input X1
p20219 BI: NSW 0 switch setting I / NSW 0 sw_setting
Access level: 3 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7250
Min Max Factory setting
- - 0
r20220 CO: NSW 0 output Y / NSW 0 output Y
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: PERCENT Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7250
Min Max Factory setting
- - -
p20221 NSW 0 run-time group / NSW 0 RTG
Access level: 3 Calculated: - Data type: Integer16
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7250
Min Max Factory setting
5 9999 9999
p20222 NSW 0 run sequence / NSW 0 RunSeq
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7250
Min Max Factory setting
0 32000 610
p20223[0...1] CI: NSW 1 inputs / NSW 1 inputs
Access level: 3 Calculated: - Data type: U32 / FloatingPoint32
Can be changed: T Scaling: PERCENT Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7250
Min Max Factory setting
- - 0