EasyManua.ls Logo

Siemens SINAMICS G120 - p0531[0...n] Bearing code number selection; Bearing codeNo sel; p0532[0...n] Bearing maximum speed; Bearing n_max; p0541[0...n] Load gearbox code number; Load grbx CodeNo

Siemens SINAMICS G120
924 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2 Parameters
2.2 List of parameters
SINAMICS G120 Control Units CU240B-2/CU240E-2
88 List Manual (LH11), 01/2016, A5E33839529
101 = STANDARD
102 = PERFORMANCE
103 = HIGH PERFORMANCE
104 = ADVANCED LIFETIME
Dependency: Refer to: p0301, p0531, p0532, p1082
Notice: For p0530 = 101, 102, 103, 104, the maximum bearing speed (p0532) is write protected. Write protection is
withdrawn with p0530 = 1.
If p0530 is changed during quick commissioning (p0010 = 1), then the maximum speed p1082, which is also
associated with quick commissioning, is pre-assigned appropriately. This is not the case when commissioning the
motor (p0010 = 3). The maximum speed of the bearing is factored into the limit for the maximum speed p1082.
Note: For a motor with DRIVE-CLiQ, p0530 can only be set to 1.
Description: Display and setting the code number of the bearing.
When setting p0301 and p0530 the code number is automatically pre-assigned and is write protected. The
information in p0530 should be observed when removing write protection.
Dependency: Refer to: p0301, p0530, p0532, p1082
Notice: If p0531 is changed during quick commissioning (p0010 = 1), then the maximum speed p1082, which is also
associated with quick commissioning, is pre-assigned appropriately. This is not the case when commissioning the
motor (p0010 = 3). The maximum speed of the bearing is factored into the limit for the maximum speed p1082.
Note: p0531 cannot be changed on a motor with DRIVE-CLiQ.
Description: Sets the maximum speed of the bearing.
The following applies when calculating the maximum speed (p1082):
- for p0324 = 0 or p0532 = 0, p0322 is used.
- for p0324 > 0 and p0532 > 0, the minimum value from the two parameters is used.
Dependency: Refer to: p0301, p0322, p0530, p1082
Notice: This parameter is pre-assigned in the case of motors from the motor list (p0301) if a bearing version (p0530) is
selected.
When selecting a catalog motor, this parameter cannot be changed (write protection). The information in p0530
should be observed when removing write protection.
If p0532 is changed during quick commissioning (p0010 = 1), then the maximum speed p1082, which is also
associated with quick commissioning, is pre-assigned appropriately. This is not the case when commissioning the
motor (p0010 = 3).
Description: Display and setting the code number of the load gearbox.
p0531[0...n] Bearing code number selection / Bearing codeNo sel
PM240 Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: C(3) Scaling: - Dyn. index: MDS, p0130
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
0 65535 0
p0532[0...n] Bearing maximum speed / Bearing n_max
PM240 Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: C(1, 3) Scaling: - Dyn. index: MDS, p0130
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
0.0 [rpm] 210000.0 [rpm] 0.0 [rpm]
p0541[0...n] Load gearbox code number / Load grbx CodeNo
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: T Scaling: - Dyn. index: MDS
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
0 4294967295 0

Table of Contents