3 Function diagrams
3.10 Safety Integrated Extended Functions
SINAMICS G120 Control Units CU240B-2/CU240E-2
640 List Manual (LH11), 01/2016, A5E33839529
Fig. 3-70 2823 – SSM (Safe Speed Monitor)
r9714
SI Mtn diag v P1 [rpm]
- 2823 -
Function diagram
87654321
fp_2823_97_58.vsd
Safety Integrated Extended Functions
CU240E-2 DP_F/PN_F
09.12.2015 V4.7.6
SSM (Safe Speed Monitor)
1
0
SI Mtn SSM filt P1
0.00 ... 100.00 [ms]
p9545 (0.00)
SI Mtn SSM filt P2
0.00 ... 100000.00 [µs]
p9345 (0.00)
SI Mtn SSM v_limP1
0.00 ... 100000.00 [rpm]
p9546 (20.00)
SI Mtn SSM hyst P1
0.0010 ... 500.0000 [rpm]
p9547 (10.0000)
SI Mtn SSM v_limP2
0.00 ... 100000.00 [rpm]
p9346 (20.00)
SI Mtn SSM Hyst P2
0.0010 ... 500.0000 [rpm]
p9347 (10.0000)
SI Mtn int stat P1
r9722
r9722
.15
0
1
0
1
[0]
1 = SSM
(Speed below limit value)
[2840.5]
SI Mtn enable P1
p9501.16
SI Mtn enable P2
p9301.16