EasyManua.ls Logo

Siemens SINAMICS G120 - p9661 SI forced checking procedure STO via PM terminals time; FCP_dyn STO PM­T t; r9662 SI forced checking procedure STO via PM terminals remaining time; FCP_dyn STO PM­T t; p9670 SI module identification Control Unit; Module ID CU

Siemens SINAMICS G120
924 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SINAMICS G120 Control Units CU240B-2/CU240E-2
List Manual (LH11), 01/2016, A5E33839529
421
2 Parameters
2.2 List of parameters
Description: Sets the time interval for monitoring the forced checking procedure and testing the Safety switch-off signal paths for
STO via terminals on the Power Module.
Within the parameterized time, STO must have been de-selected at least once.
Dependency: Refer to: r9662
Refer to: A01678
Note: STO: Safe Torque Off
Description: Displays the remaining time for monitoring the forced checking procedure and testing the Safety switch-off signal
paths for STO via terminals on the Power Module.
After the monitoring time set in p9661 has expired, an appropriate alarm is output.
Dependency: Refer to: p9661
Refer to: A01678
Note: PM: Power Module
STO: Safe Torque Off
Description: CRC via Node Identifier of the Control Unit.
Note: CU: Control Unit
p9661 SI forced checking procedure STO via PM terminals time / FCP_dyn STO PM-T t
PM240
PM250
PM260
CU240E-2
CU240E-2_DP
CU240E-2 PN
CU240E-2_F
CU240E-2_PN_F
CU240E-2_DP_F
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: C(95) Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
0.00 [h] 9000.00 [h] 8.00 [h]
r9662 SI forced checking procedure STO via PM terminals remaining time /
FCP_dyn STO PM-T t
PM240
PM250
PM260
CU240E-2
CU240E-2_DP
CU240E-2 PN
CU240E-2_F
CU240E-2_PN_F
CU240E-2_DP_F
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- [h] - [h] - [h]
p9670 SI module identification Control Unit / Module ID CU
PM230_STO
PM240
PM250
PM260
CU240E-2
CU240E-2_DP
CU240E-2 PN
CU240E-2_F
CU240E-2_PN_F
CU240E-2_DP_F
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
0 4294967295 0