Siemens SINAMICS G120 - p9563[0...3] SI Motion SLS-specific stop response (processor 1); SI Mtn SLS stop P1; p9564 SI Motion SDI tolerance (processor 1); SI Mtn SDI tol P1; p9565 SI Motion SDI delay time (processor 1); SI Mtn SDI t P1; p9566 SI Motion SDI stop response (processor 1); SI Mtn SDI Stop P1

Siemens SINAMICS G120
924 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SINAMICS G120 Control Units CU240B-2/CU240E-2
List Manual (LH11), 01/2016, A5E33839529
411
2 Parameters
2.2 List of parameters
Description: Sets the SLS-specific stop response for the function "Safely Limited Speed" (SLS).
These settings apply to the individual limit values for SLS.
Value: 0: STOP A
1: STOP B
Index: [0] = Limit value SLS1
[1] = Limit value SLS2
[2] = Limit value SLS3
[3] = Limit value SLS4
Dependency: Refer to: p9531
Note: SLS: Safely Limited Speed
Description: Sets the tolerance for the function "Safe motion direction" (SDI).
This motion in the monitored direction is still permissible before safety message C01716 is initiated.
Dependency: Refer to: p9565, p9566
Refer to: C01716
Note: SDI: Safe Direction (safe motion direction)
Description: Sets the delay time for the function "Safe motion direction" (SDI).
After selecting the SDI function, then for a maximum of this time, motion in the monitored direction is permissible.
This time can therefore be used for braking any motion.
Dependency: Refer to: p9564, p9566
Refer to: C01716
Note: The set time is rounded internally to an integer multiple of the monitoring clock cycle.
SDI: Safe Direction (safe motion direction)
Description: Sets the stop response for the function "Safe motion direction" (SDI).
This setting applies to both directions of motion.
p9563[0...3] SI Motion SLS-specific stop response (processor 1) / SI Mtn SLS stop P1
PM240
PM250
PM260
CU240E-2_F
CU240E-2_PN_F
CU240E-2_DP_F
Access level: 3 Calculated: - Data type: Integer16
Can be changed: C(95) Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
0 1 0
p9564 SI Motion SDI tolerance (processor 1) / SI Mtn SDI tol P1
CU240E-2_F
CU240E-2_PN_F
CU240E-2_DP_F
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: C(95) Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 2824
Min Max Factory setting
0.001 [°] 360.000 [°] 12.000 [°]
p9565 SI Motion SDI delay time (processor 1) / SI Mtn SDI t P1
PM240
PM250
PM260
CU240E-2_F
CU240E-2_PN_F
CU240E-2_DP_F
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: C(95) Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 2824
Min Max Factory setting
0.00 [ms] 600000.00 [ms] 100.00 [ms]
p9566 SI Motion SDI stop response (processor 1) / SI Mtn SDI Stop P1
PM240
PM250
PM260
CU240E-2_F
CU240E-2_PN_F
CU240E-2_DP_F
Access level: 3 Calculated: - Data type: Integer16
Can be changed: C(95) Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 2824
Min Max Factory setting
0 1 1