EasyManua.ls Logo

Siemens SINAMICS G120 - Fig. 3-50 2522 - Status word, speed controller (r1407)

Siemens SINAMICS G120
924 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SINAMICS G120 Control Units CU240B-2/CU240E-2
List Manual (LH11), 01/2016, A5E33839529
617
3 Function diagrams
3.7 Internal control/status words
Fig. 3-50 2522 – Status word, speed controller (r1407)
- 2522 -
Function diagram
87654321
fp_2522_97_02.vsd
Internal control/status words
G120 CU240B/E-2
09.12.2015 V4.7.6
Status word, speed controller (r1407)
1
2
3
...
5
6
7
8
9
10
11
0
12
13
14
15
r1407.8
r1407.9
r1407.17
r1407.1
r1407.7
r1407.10
r1407.11
r1407.5
r1407.6
r1407.2
r1407.3
r1407.12
r1407.13
r1407.0
From the changeover,
closed-loop control types
Status word, speed controller (r1407)Bit No.
1 = U/f control active
1 = Sensorless operation active
1 = Closed-loop torque control active
1 = Closed-loop speed control active
1 = Speed controller, I component held
1 = Speed controller, I component set
1 = Torque limit reached
1 = Torque limiting, upper, active
1 = Torque limiting, lower, active
1 = Droop enabled
1 = Speed setpoint limited
1 = Ramp-function generator set
1 = Sensorless operation due to a fault
1 = I/f control active
1 = Torque limit reached (without pre-control)
To speed setpoint, droop [6030.6]
To speed signals 2 [8011.4]
To ramp-function generator tracking [3080.1]
To speed controller [6040.4]
To motor locked/stalled [8012.5]
From the speed setpoint, droop [6030.4], [6030.5]
From the speed setpoint, droop [6030.3]
From the torque setpoint [6060.5], [6060.8]
From the speed controller [6040.7]
From the speed controller [6040.7]
ZSW n_ctrl
r1407
r1407
Reserved
From the torque setpoint [6060.8]
...
17
Reserved
1 = Speed limiting control activeFrom the speed limiting [6640.8]
r1407.14
r1407.15
From the torque setpoint [6060.5]
From the speed controller [6040.7]
From the torque setpoint [6060.5], [6060.8]
From the torque setpoint [6060.3]
r1407.2323
1 = Acceleration model activated
r1407.2424
r1407.2525
r1407.2626
r1407.2727
1 = Moment of inertia estimator active
1 = Moment of inertia estimator stabilized
1 = moment of inertia estimator is actively accelerating the motor
1 = Load estimator active
...
Reserved
From the moment of inertia estimator [6035.4], [6823.4]
From the moment of inertia estimator [6035.4], [6823.4]
From the moment of inertia estimator [6035.4], [6823.4]