Siemens SINAMICS G120 - p5612[0...1] Pe energy-saving properties mode-dependent; Pe properties mod; r5613.0...1 CO;BO: Pe energy-saving active;inactive; Pe save act;inact; p5614 BI: Pe set switching-on inhibited signal source; Pe sw on_inh s_src; r7758[0...19] KHP Control Unit serial number; KHP CU ser_no

Siemens SINAMICS G120
924 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2 Parameters
2.2 List of parameters
SINAMICS G120 Control Units CU240B-2/CU240E-2
372 List Manual (LH11), 01/2016, A5E33839529
Note: Pe: PROFIenergy profiles
PROFIdrive state S4: operation
Description: Sets the mode-dependent properties for energy-saving.
Index: [0] = Reserved
[1] = Mode 2
Note: Pe: PROFIenergy profiles
Description: Display and binector output for the state display PROFIenergy energy saving active or inactive.
Note: Bit 0 and bit 1 are inverse of one another.
Pe: PROFIenergy profiles
Description: Sets the signal source to set in the PROFIdrive state S1 "switching-on inhibited".
Dependency: Refer to: r5613
Note: Pe: PROFIenergy profiles
Description: Displays the actual serial number of the Control Unit.
Bit field: Bit Signal name 1 signal 0 signal FP
00 Inhibit PROFIenergy control commands Yes No -
01 Drive initiates OFF1 when transitioning to
energy-saving mode
Yes No -
02 Trans to energy-saving mode from
PROFIdrive state S3/S4 poss
Yes No -
p5612[0...1] Pe energy-saving properties mode-dependent / Pe properties mod
CU240E-2 PN
CU240E-2_PN_F
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- - [0] 0110 bin
[1] 0000 bin
Bit field: Bit Signal name 1 signal 0 signal FP
00 Reserved Yes No -
r5613.0...1 CO/BO: Pe energy-saving active/inactive / Pe save act/inact
CU240E-2 PN
CU240E-2_PN_F
Access level: 3 Calculated: - Data type: Unsigned8
Can be changed: - Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 2382
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Pe active Yes No -
01 Pe inactive Yes No -
p5614 BI: Pe set switching-on inhibited signal source / Pe sw on_inh s_src
CU240E-2 PN
CU240E-2_PN_F
Access level: 3 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 2382
Min Max Factory setting
- - 0
r7758[0...19] KHP Control Unit serial number / KHP CU ser_no
Access level: 3 Calculated: - Data type: Unsigned8
Can be changed: - Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- - -