SINAMICS G120 Control Units CU240B-2/CU240E-2
List Manual (LH11), 01/2016, A5E33839529
509
2 Parameters
2.2 List of parameters
Description: Setting parameter for the run sequence of instance LVM 0 within the run-time group set in p20273.
Note: The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description: Sets the signal source of input quantity X of instance LVM 1 of the double-sided limiter.
Description: Setting parameter for the interval average M of instance LVM 1 of the double-sided limiter.
Description: Setting parameter for the interval limit L of instance LVM 1 of the double-sided limiter.
Description: Setting parameter for hysteresis HY of instance LVM 1 of the double-sided limiter.
Description: Display parameter of instance LVM 1 of the double-sided limiter that input quantity X was at least once X > M + L and
X is >= M + L - HY.
p20274 LVM 0 run sequence / LVM 0 RunSeq
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7270
Min Max Factory setting
0 7999 720
p20275 CI: LVM 1 input X / LVM 1 input X
Access level: 3 Calculated: - Data type: U32 / FloatingPoint32
Can be changed: T Scaling: PERCENT Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7270
Min Max Factory setting
- - 0
p20276 LVM 1 interval average value M / LVM 1 avg value M
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7270
Min Max Factory setting
-340.28235E36 340.28235E36 0.0000
p20277 LVM 1 interval limit L / LVM 1 limit L
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7270
Min Max Factory setting
-340.28235E36 340.28235E36 0.0000
p20278 LVM 1 hyst HY / LVM 1 hyst HY
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7270
Min Max Factory setting
-340.28235E36 340.28235E36 0.0000
r20279 BO: LVM 1 input quantity above interval QU / LVM 1 X above QU
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7270
Min Max Factory setting
- - -