SINAMICS G120 Control Units CU240B-2/CU240E-2
List Manual (LH11), 01/2016, A5E33839529
569
3 Function diagrams
3.3 Input/output terminals
Fig. 3-6 2202 – Connection overview G120 CU240E-2
- 2202 -
Function diagram
87654321
fp_2202_97_02.vsd
Input/Output Terminals
G120 CU240E-2
09.12.2015 V4.7.6
Connection overview G120 CU240E-2
Simulation for DI 0 ... DI 12, DI 11 … DI 12
1
0
1
r0721
p0796
CU DI status inv
r0723
r0723
CU DI status
r0722
r0722
CU DI simulation
p0795
1 = Simulation on
T0
[2221]
6 Digital inputs
2 Analog outputs[2261]
&
+24 V OUTKl. 9
Kl. 28
Kl. 69
GND
DI COM
CU DI t_debounce
p0724
.0...12
.0...12
.0...12
.0...12
.0...12
Kl. = Terminal
Kl. 34 DI COM2
2 Analog inputs[2251]
+10 V OUTKl. 1
Kl. 2 GND
Kl. 5
Kl. 6
DI 0
DI 1
CU DI status
r0722
r0722
Kl. 7
Kl. 8
DI 3
DI 2
Kl. 16
Kl. 17
DI 5
DI 4
CU DI status inv
r0723
r0723
1
CU DI status
r0722
r0722
CU DI status inv
r0723
r0723
1
...
.0
.0
.5
.5
24 V
5 V
...
D
A
D
A
CU AO S_src
(27[0])
p0771
CU AO S_src
(21[0])
p0771
AO 0
AO 1
Kl. 12
Kl. 26
[0]
[1]
3 Digital outputs
DO 1
(52.7)
CU S_src DO 1
p0731
(52.3)
CU S_src DO 0
p0730
[2242]
(52.2)
CU S_src DO 2
p0732
NO
COM
NC
Kl. 20
Kl. 19
Kl. 18
DO 0
Kl. 21
Kl. 22
NO
COM
DO 2
NO
COM
NC
Kl. 25
Kl. 24
Kl. 23
<1> If the Safety Integrated Extended Functions are activated, can also be used as F-DI, see [2850].
<1>
<1>
<1>
<1>
<1>
<1>
CU DO inv
p0748
Kl. 14
Kl. 15
T1 MOTOR
T2 MOTOR
A
D
r0035
Mot temp [°C]
[2]
[8016] Thermal monitoring, motor
1
0
1
1
0
1
1
0
1
A
D
r0755
CU AI value in % [%]
[0]
Kl. 4
Kl. 3
AI 0+
AI 0-
A
D
r0755
CU AI value in % [%]
[1]
Kl. 11
Kl. 10
AI 1+
AI 1-

Table of Contents