2 Parameters
2.2 List of parameters
SINAMICS G120 Control Units CU240B-2/CU240E-2
522 List Manual (LH11), 01/2016, A5E33839529
Note: The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description: Sets the signal source for the input pulse I of instance MFP 2 of the pulse generator.
Description: Setting parameter for pulse duration T in milliseconds of instance MFP 2 of the pulse generator.
Description: Display parameter for output pulse Q of instance MFP 2 of the pulse generator.
Description: Setting parameter for the run-time group in which the instance MFP 2 of the pulse generator is to be called.
Value: 5: Run-time group 5
6: Run-time group 6
9999: Do not calculate
Description: Setting parameter for the run sequence of instance MFP 2 within the run-time group set in p20357.
Note: The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
p20354 BI: MFP 2 input pulse I / MFP 2 inp_pulse I
Access level: 3 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7230
Min Max Factory setting
- - 0
p20355 MFP 2 pulse duration in ms / MFP 2 pulse_dur ms
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7230
Min Max Factory setting
0.00 5400000.00 0.00
r20356 BO: MFP 2 output Q / MFP 2 output Q
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7230
Min Max Factory setting
- - -
p20357 MFP 2 run-time group / MFP 2 RTG
Access level: 3 Calculated: - Data type: Integer16
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7230
Min Max Factory setting
5 9999 9999
p20358 MFP 2 run sequence / MFP 2 RunSeq
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7230
Min Max Factory setting
0 32000 950