EasyManua.ls Logo

Siemens SINAMICS G120 - r0084[0...1] CO: Flux actual value; Flux act val; r0087 CO: Actual power factor; Cos phi act; r0089[0...2] Actual phase voltage; U_phase act val; r0094 CO: Transformation angle; Transformat_angle

Siemens SINAMICS G120
924 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SINAMICS G120 Control Units CU240B-2/CU240E-2
List Manual (LH11), 01/2016, A5E33839529
49
2 Parameters
2.2 List of parameters
Description: Displays the flux actual value.
Index: [0] = Unsmoothed
[1] = Smoothed
Description: Displays the actual active power factor.
This value refers to the electrical power of the basic fundamental signals at the output terminals of the converter.
Description: Displays the actual phase voltage.
Index: [0] = Phase U
[1] = Phase V
[2] = Phase W
Note: The values are determined from the transistor switch-on duration.
Description: Displays the transformation angle.
Dependency: Refer to: r1778
Note: The transformation angle corresponds to the electrical commutation angle.
Description: Setting the commissioning and control view for various application classes.
Value: 0: Expert
1: Standard Drive Control (SDC)
2: Dynamic Drive Control (DDC)
r0084[0...1] CO: Flux actual value / Flux act val
Access level: 4 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: PERCENT Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 6730, 6731
Min Max Factory setting
- [%] - [%] - [%]
r0087 CO: Actual power factor / Cos phi act
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- - -
r0089[0...2] Actual phase voltage / U_phase act val
Access level: 4 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: p2001 Dyn. index: -
Unit group: 5_3 Unit selection: p0505 Func. diagram: 6719
Min Max Factory setting
- [V] - [V] - [V]
r0094 CO: Transformation angle / Transformat_angle
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: p2005 Dyn. index: -
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- [°] - [°] - [°]
p0096 Application class / Appl_class
PM240 Access level: 1 Calculated: - Data type: Integer16
Can be changed: C(1) Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 6019
Min Max Factory setting
0 2 0