2 Parameters
2.2 List of parameters
SINAMICS G120 Control Units CU240B-2/CU240E-2
478 List Manual (LH11), 01/2016, A5E33839529
Description: Setting parameter for the run sequence of instance SUB 1 within the run-time group set in p20108.
Note: The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description: Sets the signal source of the factors X0, X1, X2, X3 of instance MUL 0 of the multiplier.
Index: [0] = Factor X0
[1] = Factor X1
[2] = Factor X2
[3] = Factor X3
Description: Display parameter for the product Y = X0 * X1 * X2 * X3 of instance MUL 0 of the multiplier.
Description: Setting parameter for the run-time group in which instance MUL 0 of the multiplier is to be called.
Value: 5: Run-time group 5
6: Run-time group 6
9999: Do not calculate
Description: Setting parameter for the run sequence of instance MUL 0 within the run-time group set in p20112.
Note: The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
p20109 SUB 1 run sequence / SUB 1 RunSeq
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7220
Min Max Factory setting
0 32000 250
p20110[0...3] CI: MUL 0 inputs / MUL 0 inputs
Access level: 3 Calculated: - Data type: U32 / FloatingPoint32
Can be changed: T Scaling: PERCENT Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7222
Min Max Factory setting
- - 0
r20111 CO: MUL 0 product Y / MUL 0 product Y
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: PERCENT Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7222
Min Max Factory setting
- - -
p20112 MUL 0 run-time group / MUL 0 RTG
Access level: 3 Calculated: - Data type: Integer16
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7222
Min Max Factory setting
5 9999 9999
p20113 MUL 0 run sequence / MUL 0 RunSeq
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7222
Min Max Factory setting
0 32000 270