SINAMICS G120 Control Units CU240B-2/CU240E-2
List Manual (LH11), 01/2016, A5E33839529
439
2 Parameters
2.2 List of parameters
Description: Display to diagnose acceleration values of the encoderless actual values sensing.
Index: [0] = Setpoint acceleration value
[1] = Actual acceleration value
Dependency: Refer to: p9589
Note: For index 0:
Shows the parameterized acceleration value of p9589.
For index 1:
Shows the actually measured acceleration values of the encoderless actual value sensing
Description: Display to diagnose currents of the encoderless actual value sensing.
Index: [0] = Minimum current parameterized
[1] = Minimum current measured
Dependency: Refer to: p9588
Note: For index 0:
Displays the parameterized minimum current of p9588.
For index 1:
Displays the currently measured current of the encoderless actual value sensing
Description: Display to diagnose the angle for sensorless actual value sensing.
Index: [0] = Plausibility angle actual value
[1] = Voltage angle actual value
[2] = Current angle actual value
Dependency: Refer to: p9585
Note: For index 0:
Displays the actual plausibility angle.
For index 1:
Displays the actual voltage angle.
For index 2:
Displays the actual current angle.
r9784[0...1] SI Motion diagnostics sensorless acceleration / Diag sl a
PM240
PM250
PM260
CU240E-2_F
CU240E-2_PN_F
CU240E-2_DP_F
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- [rev/s²] - [rev/s²] - [rev/s²]
r9785[0...1] SI Motion diagnostics sensorless minimum current / Diag sl I_min
PM240
PM250
PM260
CU240E-2_F
CU240E-2_PN_F
CU240E-2_DP_F
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: - Dyn. index: -
Unit group: 6_3 Unit selection: p0505 Func. diagram: -
Min Max Factory setting
- [mA] - [mA] - [mA]
r9786[0...2] SI Motion diagnostics sensorless angle / Diag sl angle
PM240
PM250
PM260
CU240E-2_F
CU240E-2_PN_F
CU240E-2_DP_F
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- [°] - [°] - [°]