EasyManua.ls Logo

Siemens SINAMICS G120 - Fig. 3-181 8565 - Drive Data Sets (DDS)

Siemens SINAMICS G120
924 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3 Function diagrams
3.21 Data sets
SINAMICS G120 Control Units CU240B-2/CU240E-2
762 List Manual (LH11), 01/2016, A5E33839529
Fig. 3-181 8565 – Drive Data Sets (DDS)
- 8565 -
Function diagram
87654321
fp_8565_97_54.vsd
Data sets
G120 CU240B/E-2
09.12.2015 V4.7.6
Drive Data Sets (DDS)
DDS3
DDS2
DDS1
DDS0
r0837.1
r0051.1
<1>
A07530 "Drive data set does not exist"
(0)
DDS select., bit 0
p0820 [C]
(0)
DDS select., bit 1
p0821 [C]
DDS count
1 ... 4
p0180 (1)
DDS selected
r0837
r0837
DDS effective
r0051
r0051
Copy DDS, source
p0819[0] (0)
Copy DDS, start
p0819[2] (0)
Copy DDS, target
p0819[1] (1)
.0
.0
[2513.2]
A BICO interconnection to a parameter which is part of a drive data set always influences the currently effective data set.
Data sets can only be applied and cleared when p0010 = 15 is set.<2>
<1>
<2>

Table of Contents

Other manuals for Siemens SINAMICS G120

Related product manuals