EasyManua.ls Logo

Siemens SINAMICS G120 - r20280 BO: LVM 1 input quantity within interval QM; LVM 1 X within QM; r20281 BO: LVM 1 input quantity below interval QL; LVM 1 X below QL; p20282 LVM 1 run-time group; LVM 1 RTG; p20283 LVM 1 run sequence; LVM 1 RunSeq

Siemens SINAMICS G120
924 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2 Parameters
2.2 List of parameters
SINAMICS G120 Control Units CU240B-2/CU240E-2
510 List Manual (LH11), 01/2016, A5E33839529
Description: Display parameter of instance LVM 1 of the double-sided limiter that the input quantity X lies within the interval.
Description: Display parameter of instance LVM 1 of the double-sided limiter that input quantity X was at least once X < M - L and
X is <= M - L + HY.
Description: Setting parameter for the run-time group in which instance LVM 1 of the double-sided limiter is to be called.
Value: 5: Run-time group 5
6: Run-time group 6
9999: Do not calculate
Description: Setting parameter for the run sequence of instance LVM 1 within the run-time group set in p20282.
Note: The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description: Sets the signal source of input quantity X of instance DIF 0 of the differentiating element.
r20280 BO: LVM 1 input quantity within interval QM / LVM 1 X within QM
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7270
Min Max Factory setting
- - -
r20281 BO: LVM 1 input quantity below interval QL / LVM 1 X below QL
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7270
Min Max Factory setting
- - -
p20282 LVM 1 run-time group / LVM 1 RTG
Access level: 3 Calculated: - Data type: Integer16
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7270
Min Max Factory setting
5 9999 9999
p20283 LVM 1 run sequence / LVM 1 RunSeq
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7270
Min Max Factory setting
0 7999 730
p20284 CI: DIF 0 input X / DIF 0 input X
Access level: 3 Calculated: - Data type: U32 / FloatingPoint32
Can be changed: T Scaling: PERCENT Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7264
Min Max Factory setting
- - 0

Table of Contents

Other manuals for Siemens SINAMICS G120

Related product manuals