SINAMICS G120 Control Units CU240B-2/CU240E-2
List Manual (LH11), 01/2016, A5E33839529
525
2 Parameters
2.2 List of parameters
[16] = Breakpoint 16
[17] = Breakpoint 17
[18] = Breakpoint 18
[19] = Breakpoint 19
Description: Setting parameter for the run-time group in which instance PLI 0 of the polyline is to be called
Value: 5: Run-time group 5
6: Run-time group 6
9999: Do not calculate
Description: Setting parameter for the run sequence of instance PLI 0 within the run-time group set in p20376.
Note: The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description: Sets the signal source for input X of the polyline (20 breakpoints) of instance PLI 1.
Description: Display parameter for the output quantity Y of the polyline (20 breakpoints) of instance PLI 1
Description: Sets the x-coordinates for the breakpoints (A0...A19) of the polyline (20 breakpoints) of instance PLI 1.
Index: [0] = Breakpoint 0
[1] = Breakpoint 1
[2] = Breakpoint 2
[3] = Breakpoint 3
[4] = Breakpoint 4
[5] = Breakpoint 5
p20376 PLI 0 run-time group / PLI 0 RTG
Access level: 3 Calculated: - Data type: Integer16
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7226
Min Max Factory setting
5 9999 9999
p20377 PLI 0 run sequence / PLI 0 RunSeq
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7226
Min Max Factory setting
0 32000 980
p20378 CI: PLI 1 input X / PLI 1 input X
Access level: 3 Calculated: - Data type: U32 / FloatingPoint32
Can be changed: T Scaling: PERCENT Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7226
Min Max Factory setting
- - 0
r20379 CO: PLI 1 output Y / PLI 1 output Y
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: PERCENT Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7226
Min Max Factory setting
- - -
p20380[0...19] PLI 1 X-coordinate, A breakpoint / PLI 1 X-coordinate
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: T Scaling: PERCENT Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 7226
Min Max Factory setting
-340.28235E36 340.28235E36 0.0000