EasyManua.ls Logo

Siemens SINAMICS G120 - 2.5.3 Parameters with KHP_ACTIVE_READ

Siemens SINAMICS G120
924 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2 Parameters
2.5 Parameters for write protection and know-how protection
SINAMICS G120 Control Units CU240B-2/CU240E-2
552 List Manual (LH11), 01/2016, A5E33839529
p8980 Ethernet/IP profile / Eth/IP profile
p8981 Ethernet/IP ODVA STOP mode / Eth/IP ODVA STOP
p8982 Ethernet/IP ODVA speed scaling / Eth/IP ODVA n scal
p8983 Ethernet/IP ODVA torque scaling / Eth/IP ODVA M scal
p9400 Safely remove memory card / Mem_card rem
p9484 BICO interconnections search signal source / BICO S_src srch
2.5.3 Parameters with "KHP_ACTIVE_READ"
The following list contains the parameters with the "KHP_ACTIVE_READ" attribute.
These parameters can also be read with activated know-how protection.
Product: SINAMICS G120 CU240, Version: 4707900, Language: eng, Type: KHP_ACTIVE_READ
p0015 Macro drive unit / Macro drv unit
p0100 IEC/NEMA mot stds / IEC/NEMA mot stds
p0170 Number of Command Data Sets (CDS) / CDS count
p0180 Number of Drive Data Sets (DDS) / DDS count
p0300[0...n] Motor type selection / Mot type sel
p0304[0...n] Rated motor voltage / Mot U_rated
p0305[0...n] Rated motor current / Mot I_rated
p0505 Selecting the system of units / Unit sys select
p0595 Technological unit selection / Tech unit select
p0730 BI: CU signal source for terminal DO 0 / CU S_src DO 0
p0731 BI: CU signal source for terminal DO 1 / CU S_src DO 1
p0732 BI: CU signal source for terminal DO 2 / CU S_src DO 2
p0806 BI: Inhibit master control / PcCtrl inhibit
p0922 PROFIdrive PZD telegram selection / PZD telegr_sel
p1080[0...n] Minimum speed / n_min
p1082[0...n] Maximum speed / n_max
p1520[0...n] CO: Torque limit upper / M_max upper
p2000 Reference speed reference frequency / n_ref f_ref
p2001 Reference voltage / Reference voltage
p2002 Reference current / I_ref
p2003 Reference torque / M_ref
p2005 Reference angle / Reference angle
p2006 Reference temp / Ref temp
p2007 Reference acceleration / a_ref
p2030 Field bus int protocol selection / Field bus protocol
p2038 PROFIdrive STW/ZSW interface mode / PD STW/ZSW IF mode
p2079 PROFIdrive PZD telegram selection extended / PZD telegr ext
p7763 KHP OEM exception list number of indices for p7764 / KHP OEM qty p7764
p7764[0...n] KHP OEM exception list / KHP OEM excep list
p9601 SI enable functions integrated in the drive (processor 1) / SI enable fct P1
p9810 SI PROFIsafe address (processor 2) / SI PROFIsafe P2

Table of Contents

Other manuals for Siemens SINAMICS G120

Related product manuals