2 Parameters
2.2 List of parameters
SINAMICS G120 Control Units CU240B-2/CU240E-2
410 List Manual (LH11), 01/2016, A5E33839529
Description: Sets the delay time for STOP A after STOP B.
Dependency: Refer to: p9560
Refer to: C01701
Note: The set time is rounded internally to an integer multiple of the monitoring clock cycle.
Description: Sets the maximum time for the acceptance test mode.
If the acceptance test mode takes longer than the selected time limit, then the mode is automatically terminated.
Dependency: Refer to: C01799
Note: The set time is rounded internally to an integer multiple of the monitoring clock cycle.
Description: Sets the time interval for carrying out the forced checking procedure and testing the safety motion monitoring
functions integrated in the drives.
Within the parameterized time, the safety functions must have been tested at least once (including de-selection of the
"STO" function).
This monitoring time is reset each time the test is carried out.
The signal source to initiate the forced checking procedure is set in p9705.
Dependency: Refer to: p9705
Refer to: A01697, C01798
Note: STO: Safe Torque Off
Description: Sets the shutdown speed for the pulse suppression.
Below this speed "standstill" is assumed and for STOP B / SS1, the pulses are suppressed (by changing to STOP A).
Dependency: Refer to: p9556
Note: The shutdown speed has no effect for a value = 0.
SS1: Safe Stop 1
p9556 SI Motion pulse suppression delay time (processor 1) / SI Mtn IL t_del P1
PM240
PM250
PM260
CU240E-2_F
CU240E-2_PN_F
CU240E-2_DP_F
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: C(95) Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 2819
Min Max Factory setting
0.00 [ms] 3600000.00 [ms] 600000.00 [ms]
p9558 SI Motion acceptance test mode time limit (processor 1) / SI Mtn acc t P1
PM240
PM250
PM260
CU240E-2_F
CU240E-2_PN_F
CU240E-2_DP_F
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: C(95) Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
5000.00 [ms] 100000.00 [ms] 40000.00 [ms]
p9559 SI Motion forced checking procedure timer (processor 1) / SI Mtn dyn timer
PM240
PM250
PM260
CU240E-2_F
CU240E-2_PN_F
CU240E-2_DP_F
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: C(95) Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
0.00 [h] 9000.00 [h] 8.00 [h]
p9560 SI Motion pulse suppression shutdown speed (processor 1) / SI Mtn IL v_sh P1
CU240E-2_F
CU240E-2_PN_F
CU240E-2_DP_F
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: C(95) Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: -
Min Max Factory setting
10.00 [rpm] 6000.00 [rpm] 10.00 [rpm]