EasyManua.ls Logo

Siemens SINAMICS G120 - r5600 Pe energy-saving mode ID; Pe mode ID; p5602[0...1] Pe energy-saving mode pause time minimal; Pe mod t_pause min; p5606[0...1] Pe energy-saving mode time of maximum stay; Pe t_max_stay; p5611 Pe energy-saving properties general; Pe properties gen

Siemens SINAMICS G120
924 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SINAMICS G120 Control Units CU240B-2/CU240E-2
List Manual (LH11), 01/2016, A5E33839529
371
2 Parameters
2.2 List of parameters
Description: Displays the PROFIenergy mode ID of the effective energy-saving mode.
Value: 0: POWER OFF
2: Energy-saving mode 2
240: Operation
255: Ready
Note: Pe: PROFIenergy profiles
Description: Sets the minimum possible pause time for the energy-saving mode.
The value is the sum of the following times:
- Energy-saving mode transition time
- Operating state transition time regular
- Energy-saving mode, time of minimum stay
Index: [0] = Reserved
[1] = Mode 2
Note: It is not permissible that the value is less than the sum of the "energy-saving mode transition time" and the "operating
state transition time" (system properties).
Pe: PROFIenergy profiles
Description: Sets the time of maximum stay for the energy-saving mode.
Index: [0] = Reserved
[1] = Mode 2
Note: Pe: PROFIenergy profiles
Description: Sets the general properties for energy-saving.
r5600 Pe energy-saving mode ID / Pe mode ID
CU240E-2 PN
CU240E-2_PN_F
Access level: 3 Calculated: - Data type: Integer16
Can be changed: - Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 2381, 2382
Min Max Factory setting
0 255 -
p5602[0...1] Pe energy-saving mode pause time minimal / Pe mod t_pause min
CU240E-2 PN
CU240E-2_PN_F
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 2381
Min Max Factory setting
300000 [ms] 4294967295 [ms] [0] 300000 [ms]
[1] 480000 [ms]
p5606[0...1] Pe energy-saving mode time of maximum stay / Pe t_max_stay
CU240E-2 PN
CU240E-2_PN_F
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 2381
Min Max Factory setting
0 [ms] 4294967295 [ms] 4294967295 [ms]
p5611 Pe energy-saving properties general / Pe properties gen
CU240E-2 PN
CU240E-2_PN_F
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 2381, 2382
Min Max Factory setting
- - 0000 bin