EasyManua.ls Logo

Siemens SINAMICS G120 - Fig. 3-78 3001 - Overview

Siemens SINAMICS G120
924 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3 Function diagrams
3.12 Setpoint channel
SINAMICS G120 Control Units CU240B-2/CU240E-2
650 List Manual (LH11), 01/2016, A5E33839529
Fig. 3-78 3001 – Overview
- 3001 -
Function diagram
87654321
fp_3001_97_53.vsd
Setpoint channel
G120 CU240B/E-2
09.12.2015 V4.7.6
Overview
+
+
+ / -
+
p1076
p1071
pos
neg
(-1)
1
0
+
+
+
Main setpoint
(2050[1])
p1070 [C]
Suppl setp
(0)
p1075 [C]
r1024
n_set_fixed eff [rpm]
Jog 1 n_set
-210000.000 ... 210000.000 [rpm]
p1058 [D] (150.000)
Jog 2 n_set
-210000.000 ... 210000.000 [rpm]
p1059 [D] (-150.000)
raise
Main/supplementary setpoint, setpoint
scaling, jogging
r1050
Mop setp after RFG [rpm]
Motorized potentiometer
Fixed speed setpoints
Extended ramp-function
generator
Basic ramp-function
generator
n_set_1
n_set_4
n_set_5
Simulate ramp-function generator
Ramp-function generator selection,
status word, tracking
Direction of rotating
limiting/changeover
Skip (suppression)
bandwidth and speed limiting
Ramp-function
generator
tracking
STW seq_ctrl
r0898
r0898
STW seq_ctrl
r0898
r0898
.9
RFG selection
0 ... 1
p1115 (1)
r1150
RFG n_set at outp [rpm]
n_act
M_limit
n_ctrl n_set 1
(0)
p1155 [C]
RFG ZSW
r1199
r1199
n_ctrl n_set 2
(0)
p1160 [C]
r1438
n_ctrl n_set [rpm]
lower
[3010], [3011]
[3040] [3050]
[3070]
[3060]
[3080]
[3020]
r1114
Setp after limit
[rpm]
r1170
n_ctrl setp sum
[rpm]
.8
[3030]
1 0
0 1
0 0
1 1
ZSW
[6300.1]
[6850.1]
[6020.1]
[6820.1]
[8005.5]
r1119
RFG setp at inp
[rpm]

Table of Contents