SINAMICS G120 Control Units CU240B-2/CU240E-2
List Manual (LH11), 01/2016, A5E33839529
619
3 Function diagrams
3.7 Internal control/status words
Fig. 3-52 2530 – Status word, current control (r1408)
- 2530 -
Function diagram
87654321
fp_2530_97_64.vsd
Internal control/status words
G120 CU240B/E-2
09.12.2015 V4.7.6
Status word, current control (r1408)
1
2
0
[6714.5]
[6714.8] 3
4
5
6
7
8
9
10
11
12
13
14
15
[6730.3]
Status word current control (r1408)Bit No.
1 = Current controller active
1 = Id controller I comp. limitation
Reserved
1 = Voltage limitation
1 = Speed adaptation limitation
1 = Motor stalled
Reserved
ZSW I_ctrl
r1408
r1408
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
r1408.0
r1408.1
r1408.12
r1408.3
r1408.10
ZSW monitor 2
r2198
r2198
.7
[2536.7]
1 = Separately-excited synchronous motor is excited
1 = Current model SESM: Magnetizing excitation current set to 0
r1408.14
r1408.13
Reserved