EasyManua.ls Logo

Siemens SINAMICS G120 - Fig. 3-19 2381 - Control commands and interrogation commands

Siemens SINAMICS G120
924 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SINAMICS G120 Control Units CU240B-2/CU240E-2
List Manual (LH11), 01/2016, A5E33839529
583
3 Function diagrams
3.4 PROFIenergy
Fig. 3-19 2381 – Control commands and interrogation commands
- 2381 -
Function diagram
87654321
fp_2381_97_62.vsd
PROFIenergy
G120 CU240E-2_PN
09.12.2015 V4.7.6
Control commands and interrogation commands
PROFINET
Port 1
Port 2
PROFIenergy
interrogation commands
[2382]
PROFIenergy
control commands
"Start_Pause_with_time_response"
"End_Pause"
"List_Energy_Saving_Modes“
"Get_Mode“
"PEM_Status“
"PE_Identify“
"Query_Version“
"Get_Measurement_List“
"Get_Measurement_Values“
"Get_Measurement_Values_with_object_number“
"Get_Measurement_List_with_object_number“
"PEM_Status_with_CTTO“
Pe mod t_pause min
p5602
p5611.0
Ready for operation
r5600 = 255
r5600 = 2
Energy-saving mode 2
1 = Inhibit
PROFIenergy
Pause_Time
&
Time_to_pause Time_to_operate
1
0
min max
p5606
+ Time_to_pause
+ Time_to_operate
p5602
"Start_Pause"

Table of Contents

Other manuals for Siemens SINAMICS G120

Related product manuals