2 Parameters
2.4 BICO parameters (connectors/binectors)
r1119 CO: Ramp-function generator setpoint at the input / RFG setp at inp
r1149 CO: Ramp-function generator acceleration / RFG acceleration
r1150 CO: Ramp-function generator speed setpoint at the output / RFG n_set at outp
r1169 CO: Speed controller speed setpoints 1 and 2 / n_ctrl n_set 1/2
r1170 CO: Speed controller setpoint sum / n_ctrl setp sum
r1258 CO: Vdc controller output / Vdc_ctrl output
r1298 CO: Vdc controller output (U/f) / Vdc_ctrl output
r1337 CO: Actual slip compensation / Slip comp act val
r1343 CO: I_max controller frequency output / I_max_ctrl f_outp
r1348 CO: U/f control Eco factor actual value / U/f Eco fac act v
p1351[0...n] CO: Motor holding brake starting frequency / Brake f_start
r1438 CO: Speed controller speed setpoint / n_ctrl n_set
r1445 CO: Actual speed smoothed / n_act smooth
r1454 CO: Speed controller system deviation I component / n_ctrl sys dev Tn
r1468 CO: Speed controller P-gain effective / n_ctr Kp eff
r1482 CO: Speed controller I torque output / n_ctrl I-M_outp
r1490 CO: Droop feedback speed reduction / Droop n_reduction
r1493 CO: Moment of inertia total, scaled / M_inert tot scal
r1508 CO: Torque setpoint before supplementary torque / M_set bef. M_suppl
r1516 CO: Supplementary torque and acceleration torque / M_suppl + M_accel
r1518[0...1] CO: Accelerating torque / M_accel
p1520[0...n] CO: Torque limit upper / M_max upper
p1521[0...n] CO: Torque limit lower / M_max lower
p1524[0...n] CO: Torque limit upper scaling / M_max upper scal
p1525[0...n] CO: Torque limit lower scaling / M_max lower scal
r1526 CO: Torque limit upper without offset / M_max up w/o offs
r1527 CO: Torque limit lower without offset / M_max low w/o offs
r1538 CO: Upper effective torque limit / M_max upper eff
r1539 CO: Lower effective torque limit / M_max lower eff
r1547[0...1] CO: Torque limit for speed controller output / M_max outp n_ctrl
r1548[0...1] CO: Stall current limit torque-generating maximum / Isq_max stall
p1563[0...n] CO: Mom. of inertia estimator load torque direction of rotation pos. / J_est M pos
p1564[0...n] CO: Mom. of inertia estimator load torque direction of rotation neg. / J_est M neg
p1570[0...n] CO: Flux setpoint / Flex setp
r1593[0...1] CO: Field weakening controller / flux controller output / Field/Fl_ctrl outp
r1597 CO: Field weakening controller output / Field_ctrl outp
r1598 CO: Total flux setpoint / Flux setp total
r1718 CO: Isq controller output / Isq_ctrl outp
r1723 CO: Isd controller output / Isd_ctrl outp
r1732[0...1] CO: Direct-axis voltage setpoint / Direct U set
r1733[0...1] CO: Quadrature-axis voltage setpoint / Quad U set
r1770 CO: Motor model speed adaptation proportional component / MotMod n_adapt Kp
r1771 CO: Motor model speed adaptation I comp. / MotMod n_adapt Tn
r1801[0...1] CO: Pulse frequency / Pulse frequency
r1809 CO: Modulator mode actual / Modulator mode act
r2050[0...11] CO: PROFIBUS PZD receive word / PZD recv word
r2060[0...10] CO: PROFIdrive PZD receive double word / PZD recv DW
r2089[0...4] CO: Send binector-connector converter status word / Bin/con ZSW send
r2120 CO: Sum of fault and alarm buffer changes / Sum buffer changed
r2121 CO: Counter alarm buffer changes / Alrm buff changed
r2131 CO: Actual fault code / Act fault code
r2132 CO: Actual alarm code / Actual alarm code
r2169 CO: Actual speed smoothed signals / n_act smth message
p2201[0...n] CO: Technology controller fixed value 1 / Tec_ctrl fix val1
p2202[0...n] CO: Technology controller fixed value 2 / Tec_ctr fix val 2