EasyManua.ls Logo

Keysight M9421A - Ramp Up Start Level; Ramp Up End Level; Ramp Down Start Level

Keysight M9421A
2667 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3 WLAN Mode
3.8 Power vs Time Measurement
Ramp Up Start Level
It specifies the relative value between ramp up start level and max power level
measured in ramp time length.
Remote
Command
[:SENSe]:PVTime:THReshold:UP:STARt <rel_ampl>
[:SENSe]:PVTime:THReshold:UP:STARt?
Example
:PVT:THR:UP:STAR -50.0
:PVT:THR:UP:STAR?
Preset -20.00 dB
State Saved Yes
Min -120.00 dB
Max 0.00 dB
Ramp Up End Level
It specifies the relative value between ramp up end level and max power level
measured in ramp time length.
Remote
Command
[:SENSe]:PVTime:THReshold:UP:STOP <rel_ampl>
[:SENSe]:PVTime:THReshold:UP:STOP?
Example
:PVT:THR:UP:STOP -50.0
:PVT:THR:UP:STOP?
Preset -0.915 dB
State Saved Yes
Min -120.00 dB
Max 0.00 dB
Ramp Down Start Level
It specifies the relative value between ramp down start level and max power level
measured in ramp time length
Remote
Command
[:SENSe]:PVTime:THReshold:DOWN:STARt <rel_ampl>
[:SENSe]:PVTime:THReshold:DOWN:STARt?
Example
:PVT:THR:DOWN:STAR -50.0
:PVT:THR:DOWN:STAR?
Preset -0.915 dB
1397 WLAN Mode User's &Programmer's Reference