3 WLAN Mode
3.2 Channel Power Measurement
Remote
Command
:CALCulate:CHPower:LIMit:PSD:FAIL?
Example
:CALC:CHP:LIM:PSD:FAIL?
Notes Query only
When "PSD Limit" on page 280 state is OFF, the returned value is always 0 (pass)
When PSD Limit state is ON, the returned value is 0 (pass) if PSD test passes and 1(fail) if PSD test fails
3.2.8.5 Advanced
Contains controls for setting advanced functions of the instrument.
Does not appear in VXT.
Phase Noise Optimization
Lets you select the LO (local oscillator) phase noise behavior for various operating
conditions. When in Auto, selects the LO (local oscillator) phase noise behavior to
optimize dynamic range and speed for various instrument operating conditions.
For full details, see "Parameter Options, Installed Options & Ranges" on page 283
below.
Remote Command
[:SENSe]:CHPower:FREQuency:SYNThesis[:STATe] 1 | | 5
For the meaning of each numeric option value, see "Parameter Options, Installed Options & Ranges"
on page 283 below
[:SENSe]:CHPower:FREQuency:SYNThesis[:STATe]?
Example
:CHP:FREQ:SYNT 1
:CHP:FREQ:SYNT?
Dependencies Does not appear in all models. For models in which the control is not displayed, the SCPI command is
accepted for compatibility, although no action is taken
Preset 3
State Saved Saved in instrument state
Range See "Ranges" on page 287 below
Auto Function
Remote
Command
[:SENSe]:CHPower:FREQuency:SYNThesis:AUTO[:STATe] OFF | ON | 0 | 1
[:SENSe]:CHPower:FREQuency:SYNThesis:AUTO[:STATe]?
Example
:CHP:FREQ:SYNT:AUTO 1
:CHP:FREQ:SYNT:AUTO?
Preset
OFF
WLAN Mode User's &Programmer's Reference 282