3 WLAN Mode
3.6 Modulation Analysis Measurement
Min 0
Max Meas Interval I/Q Points
I/Q Rotation
Toggles the display rotation function between On and Off. If set to On, the I/Q polar
vector or I/Q polar constellation graph is rotated from 0 to 359.5 degrees.
Remote
Command
:DISPlay:EVM:VIEW[1]:WINDow[1]:TRACe:ROTation <real>
:DISPlay:EVM:VIEW[1]:WINDow[1]:TRACe:ROTation?
:DISPlay:EVM:VIEW[1]:WINDow[1]:TRACe:ROTation:STATe 0 | 1 | OFF | ON
:DISPlay:EVM:VIEW[1]:WINDow1:TRACe:ROTation:STATe?
Example
:DISP:EVM:VIEW:WIND:TRAC:ROT 45
:DISP:EVM:VIEW:WIND:TRAC:ROT?
Preset 45.0
OFF
State Saved Saved in instrument state
Range On|Off
Min 0
Max 359.5
Full Vector
Toggles the full vector display function between On and Off. If set to On, the full
vector traces, that are shown in gray, are displayed in the background of the polar
vector solid traces, which are shown in yellow. Both traces can be interpolated by
using the Interpolation key.
Remote Command
:DISPlay:EVM:VIEW[1]:WINDow[1]:TRACe:FVECtor[:STATe] 0 | 1 | OFF | ON
:DISPlay:EVM:VIEW[1]:WINDow[1]:TRACe:FVECtor[:STATe]?
Example
:DISP:EVM:VIEW:WIND:TRAC:FVEC ON
:DISP:EVM:VIEW:WIND:TRAC:FVEC?
Dependencies Grayed out if the selected view is I/Q Measured Polar Graph and the selected I/Q Polar Vec/Constln is
Constellation. Forceful message”-221 Setting conflict; Full vector is not available for Constellation
only”
Preset
OFF
State Saved Saved in instrument state
Range On | Off
WLAN Mode User's &Programmer's Reference 940