EasyManua.ls Logo

Keysight M9421A - Evaluation Option; Meas Setup Summary Table; Auto Couple; Meas Preset

Keysight M9421A
2667 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3 WLAN Mode
3.9 Spectral Flatness Measurement
Evaluation Option
This parameter allows you to choose either “magnitude of channel estimation” or
“subcarrier received values” to evaluate spectral flatness.
Remote
Command
:CALCulate:FLATness:EVALuation CESTimation | SCValues
:CALCulate:FLATness:EVALuation?
Example
:CALC:FLAT:EVAL CEST
:CALC:FLAT:EVAL?
Preset CESTimation
State Saved Yes
Range CESTimation | SCValues
Meas Setup Summary Table
The Meas Setup Summary Table lets you view and access many of the parameters in
the Meas Setup menus on one screen.
Auto Couple
The Auto Couple control immediately puts all Auto/Man functions into Auto. The
Auto Couple action is confined to the current measurement only. It does not affect
other measurements in the mode.
In the Auto state, Auto/Man functions are said to be “coupled”, meaning their value
will change depending on changes you make to other values in the measurement.
This helps ensure accurate measurements and optimum dynamic range. Auto
Couple is an immediate action function, and when it is executed, all the Auto/Man
controls for the current measurement are set to Auto and all measurement settings
coupled to the Auto/Man parameters are automatically set to their optimal value.
Remote
Command
:COUPle ALL
Example
:COUP ALL
Backwards
Compatibility
Notes
:COUPLE NONE puts all Auto/Man parameters in manual mode, decoupling all the coupled instrument
parameters. It is retained for backwards compatibility and is not recommended for making
measurements.
Meas Preset
Restores all the measurement parameters to their default values.
1493 WLAN Mode User's &Programmer's Reference

Table of Contents