3 WLAN Mode
3.3 Occupied BW Measurement
Sweep Time
Video BANDwidth VBW/RBW ratio
Upper and Lower Tone (set to Sense)
Zero span measurement Resolution Bandwidth
Zero span measurement Dwell Time
Harmonics (SA Mode only)
Parameters affected by Auto Couple are:
Resolution Bandwidth
Fundamental Frequency
Dwell Time
Range Table Resolution Bandwidths
Range Table Dwell Times
Meas Preset
Restores all measurement parameters to their default values.
Remote Command
:CONFigure:OBWidth
Example
:CONF:OBW
Max Hold (Remote Command Only)
When ON, Max Hold displays and holds the maximum responses of the current
measurement. Turn Max HoldOFF to disable the maximum hold feature.
Remote
Command
[:SENSe]:OBWidth:MAXHold ON | OFF | 1 | 0
[:SENSe]:OBWidth:MAXHold?
Example
:OBW:MAXH ON
:OBW:MAXH?
Couplings Max Hold is coupled to "Averaging On/Off" on page 406. Max Hold is activated only if Average state is