3 WLAN Mode
3.6 Modulation Analysis Measurement
Example
:EVM:AVER:COUN 1
:EVM:AVER:COUN?
Preset 10
State Saved Saved in instrument state
Min 1
Max 10000
Averaging On/Off
Turns averaging on or off.
Remote Command
[:SENSe]:EVM:AVERage[:STATe] OFF | ON | 0 | 1
[:SENSe]:EVM:AVERage[:STATe]?
Example
:EVM:AVER OFF
:EVM:AVER?
Couplings As Radio Std Detection is set to Auto, Average State is coupled to OFF
Preset
ON
State Saved Saved in instrument state
Range On|Off
Avg Mode
Selects the type of termination control used for the averaging function. This
determines the averaging action after the specified number of data acquisitions
(average count) is reached.
–
Exponential: After the average count is reached, each successive data
acquisition is exponentially weighted and combined with the existing average
–
Repeat: After reaching the average count, the averaging is reset, and a new
average is started
The default value is Exp.
Remote Command
[:SENSe]:EVM:AVERage:TCONtrol EXPonential | REPeat
[:SENSe]:EVM:AVERage:TCONtrol?
Example
:EVM:AVER:TCON REP
:EVM:AVER:TCON?
Preset
EXPonential
State Saved Saved in instrument state
Range Exponential|Repeat
969 WLAN Mode User's &Programmer's Reference