3 WLAN Mode
3.7 WLAN MIMO Modulation Analysis Measurement
Window EVM vs. Symbol Type Selection
Remote Command
:DISPlay:EVMMimo:WINDow[1]|2|…|9:TYPE STReam | CHANnel
:DISPlay:PULSe:WINDow[1]|2|…|9:TYPE ?
Example
:DISP:EVMM:WIND:TYPE STR
Dependencies It’s only available for EVM vs. Symbol window
Preset STR
State Saved Saved in instrument state
Range
STReam|CHANnel
3.7.3.2 Stream X I/Q Measured Polar
This Graph window appears in the following View:
View Marker Operation
Stream IQ Polar Yes [Symbol - (X,Y)]
3.7.3.3 IQ Polar Channel Metrics
The Channel Metrics window appears in the following View:
View Marker Operation
Stream IQ Polar No
3.7.3.4 IQ Polar Stream Metrics
The Stream Metrics window appears in the following View:
View Marker Operation
Stream I/Q Polar No
3.7.3.5 Stream X Channel Y Frequency Response
MIMO Channel frequency Response shows an overlay of all the individual Stream(X)
Channel(Y) Frequency Response trace data results. The Stream(X) Channel(Y)
Frequency Response trace is the channel frequency response for the specified
spatial stream and measurement hardware input channel, X means the stream
number, Y means the channel number. The MIMO Channel Frequency Response
trace enables each measurement stream(X) channel(Y) frequency response trace
data result to be easily viewed and compared on a single display. The number of
measurement traces will equal the total number of Stream(X) Channel(Y) Frequency