3 WLAN Mode
3.11 Monitor Spectrum Measurement
Remote
Command
[:SENSe]:MONitor:DETector:TRACe[1]|2|3:AUTO ON | OFF | 1 | 0
[:SENSe]:MONitor:DETector:TRACe[1]|2|3:AUTO?
Example
:MON:DET:TRAC2:AUTO ON
:MON:DET:TRAC2:AUTO?
Couplings When this function is ON, the "Detector" on page 1737 and "Trace Type" on page 1728 settings
automatically align as follows:
NORMal with Clear Write
AVERage with AVERage
POSitive (Peak)” with MAXHold
NEGative (Peak)” with MINHold
Preset
ON
State Saved Yes
Backwards
Compatibility
SCPI
[:SENSe]:MONitor:DETector:AUTO
Applied to Trace 1 only
1739 WLAN Mode User's &Programmer's Reference