Jitter analysis and clock data recovery
R&S
®
RTP
1029User Manual 1337.9952.02 ─ 12
Start / Stop ← Gating
Sets the start/stop time of the gate area.
Remote command:
ADVJitter<m>:SIGNal:GATE:RANGe:ABSolute:STARt on page 2266
ADVJitter<m>:SIGNal:GATE:RANGe:ABSolute:STOP on page 2266
Relative start / stop ← Gating
Sets the relative start/stop of the gate area in percent.
Remote command:
ADVJitter<m>:SIGNal:GATE:RANGe:RELative:STARt on page 2266
ADVJitter<m>:SIGNal:GATE:RANGe:RELative:STOP on page 2267
Clock / CDR
Selects if a clock or a CDR signal is used as a reference signal.
"CDR"
Uses software clock data recovery.
"Clock"
Uses an explicit clock signal. The signal has to be provided on an
additional channel.
Remote command:
ADVJitter<m>:SIGNal:REFSource on page 2263
Reference source
Selects the reference source for the clock/CDR signal.
Remote command:
ADVJitter<m>:SIGNal:CLKSource on page 2263
ADVJitter<m>:SIGNal:CDRMode on page 2262
Nominal bit rate
Sets /displays the nominal bit rate. It corresponds to the data rate of the data stream
from which the clock is to be recovered.
Remote command:
ADVJitter<m>:SIGNal:BITRate on page 2262
Software CDR Setup
Opens a dialog for configuring the CDR. For details, see Chapter 18.3, "Clock data
recovery", on page 1056.
Explicit clock
Opens a dialog to define the setting of the explicit clock.
Advanced jitter and noise (option R&S RTP- K133/K134)