EasyManua.ls Logo

Rohde & Schwarz RTP Series - Page 1218

Rohde & Schwarz RTP Series
2403 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote control commands
R&S
®
RTP
1218User Manual 1337.9952.02 ─ 12
22.8.7.5 Modular probes
The commands of this chapter are relevant for R&S RT-ZM modular probes. The com-
mands are available in firmware version 3.40 and higher.
The suffix <m> selects the input channel to which the probe is connected.
TRPRobe:SETup:PRMode............................................................................................1218
PROBe<m>:SETup:PRMode.........................................................................................1218
PROBe<m>:SETup:DMOFfset...................................................................................... 1218
PROBe<m>:SETup:CMOFfset...................................................................................... 1219
PROBe<m>:SETup:NOFFset........................................................................................ 1219
PROBe<m>:SETup:POFFset........................................................................................ 1219
PROBe<m>:SETup:TERM:STATe..................................................................................1220
PROBe<m>:SETup:TERM:MODE................................................................................. 1220
PROBe<m>:SETup:TERM:MEASure?........................................................................... 1220
PROBe<m>:SETup:TERM:ADJust.................................................................................1221
TRPRobe:SETup:PRMode <PrbMeasMd>
PROBe<m>:SETup:PRMode <MeasMode>
Sets the measurement mode of the modular probe.
Suffix:
<m>
.
1..4
Parameters:
<MeasMode> DMODe | CMODe | PMODe | NMODe
DMODe
Differential mode input voltage (V
dm
), the voltage between the
positive and negative input terminal.
CMODe
Common mode input voltage (V
cm
) , the mean voltage between
the positive and negative input terminal vs. ground.
PMODe
Positive single-ended input voltage (V
p
). the voltage between the
positive input terminal and ground.
NMODe
Negative single-ended input voltage (V
N
). the voltage between
the negative input terminal and ground.
*RST:
DMODe
Usage: Asynchronous command
PROBe<m>:SETup:DMOFfset <DMOffset>
Sets the differential offset to compensate a DC voltage applied to the positive and the
negative input terminal.
Suffix:
<m>
.
1..4
Acquisition and setup