Protocol analysis
R&S
®
RTP
825User Manual 1337.9952.02 ─ 12
"Position"
Available only if "Condition" (SEARch:TRIGger:USB:DPOPerator)
is set to equal. Specifies the position in which a special data pattern
is to be searched within the payload data packet.
"Data Condi-
tion"
Sets the operator ("equal" or "unequal", SEARch:TRIGger:USB:
DCONdition) to set a specific payload data pattern.
"Payload pat-
tern"
Specifies the payload data pattern that is to be searched.
Remote command:
SEARch:TRIGger:USB:WPAY on page 2037
SEARch:TRIGger:USB:DPOPerator on page 2028
SEARch:TRIGger:USB:DPOSition on page 2028
SEARch:TRIGger:USB:DCONdition on page 2027
SEARch:TRIGger:USB:PATT on page 2030
SC check
Searches for the selected Start (0) or Complete (1) SPLIT transaction endpoint, or X
(do not care).
Remote command:
SEARch:TRIGger:USB:WSTC on page 2038
SEARch:TRIGger:USB:STCO on page 2034
Port check
Enables the search for a port that meets specific conditions.
"Condition"
Defining a specific port number or a port number range requires to
set the operator to one of the following: equal, not equal, less than,
less than or equal, greater than, greater than or equal, in range, out
of range.
"Min"
Specifies a port number, or sets the start value of a port number
range.
"Max"
Sets the end value of a port number range if "Condition" (SEARch:
TRIGger:USB:PCONdition) is set to INRange or OORange.
Remote command:
SEARch:TRIGger:USB:WPOR on page 2038
SEARch:TRIGger:USB:PCONdition on page 2031
SEARch:TRIGger:USB:PMIN on page 2031
SEARch:TRIGger:USB:PMAX on page 2031
SEU check
Enables the search for an SEU that meets specific conditions. (For SEU, see "SEU"
on page 818.)
"Condition"
Defining a specific SEU value or an SEU value range requires to set
the operator to one of the following: equal, not equal, less than, less
than or equal, greater than, greater than or equal, in range, out of
range.
"Min"
Specifies an SEU value, or sets the start value of an SEU value
range.
USB (option R&S RTP-K60)