Configuring the Internal Baseband Source
R&S
®
SMBV100B
126User Manual 1178.4460.02 ─ 03
Remote command:
[:SOURce<hw>]:BB:DM:FILTer:PARameter:LPASs on page 718
[:SOURce<hw>]:BB:DM:FILTer:PARameter:LPASSEVM on page 718
[:SOURce<hw>]:BB:DM:FILTer:PARameter:APCO25Lsm:GAUSs on page 718
[:SOURce<hw>]:BB:DM:FILTer:PARameter:APCO25Lsm:LOWPass on page 718
Bandwidth
Determines the bandwidth of the cosine filter, so that the function in H(f) = 0 is fulfilled
for f >= (1 + Rolloff)* Bandwidth /2.
Remote command:
[:SOURce<hw>]:BB:DM:FILTer:PARameter:COSine:BANDwidth on page 718
Load User Filter
Calls the dialog "Select User Filter" for selecting a user-defined filter file with extension
*.vaf (see "User filter" on page 105). The dialog provides access to the standard file
management functions, like store, load, delete.
Remote command:
[:SOURce<hw>]:BB:DM:FLISt:SELect on page 731
[:SOURce<hw>]:BB:DM:FLISt:CATalog? on page 731
[:SOURce<hw>]:BB:DM:FLISt:DELete on page 732
3.5.3.6 Power Ramp Control Settings
Access:
► Select "Baseband > Custom Digital Modulation > General > Power Ramp Control".
Generating Custom Digital Modulated Signals