EasyManua.ls Logo

Rohde & Schwarz SMBV100B - Power Ramp Control Settings

Rohde & Schwarz SMBV100B
1030 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Configuring the Internal Baseband Source
R&S
®
SMBV100B
126User Manual 1178.4460.02 ─ 03
Remote command:
[:SOURce<hw>]:BB:DM:FILTer:PARameter:LPASs on page 718
[:SOURce<hw>]:BB:DM:FILTer:PARameter:LPASSEVM on page 718
[:SOURce<hw>]:BB:DM:FILTer:PARameter:APCO25Lsm:GAUSs on page 718
[:SOURce<hw>]:BB:DM:FILTer:PARameter:APCO25Lsm:LOWPass on page 718
Bandwidth
Determines the bandwidth of the cosine filter, so that the function in H(f) = 0 is fulfilled
for f >= (1 + Rolloff)* Bandwidth /2.
Remote command:
[:SOURce<hw>]:BB:DM:FILTer:PARameter:COSine:BANDwidth on page 718
Load User Filter
Calls the dialog "Select User Filter" for selecting a user-defined filter file with extension
*.vaf (see "User filter" on page 105). The dialog provides access to the standard file
management functions, like store, load, delete.
Remote command:
[:SOURce<hw>]:BB:DM:FLISt:SELect on page 731
[:SOURce<hw>]:BB:DM:FLISt:CATalog? on page 731
[:SOURce<hw>]:BB:DM:FLISt:DELete on page 732
3.5.3.6 Power Ramp Control Settings
Access:
Select "Baseband > Custom Digital Modulation > General > Power Ramp Control".
Generating Custom Digital Modulated Signals

Table of Contents

Related product manuals