EasyManua.ls Logo

Rohde & Schwarz SMBV100B - General Carrier Settings

Rohde & Schwarz SMBV100B
1030 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Configuring the Internal Baseband Source
R&S
®
SMBV100B
242User Manual 1178.4460.02 ─ 03
The remote commands required to define these settings are described in Chap-
ter 12.16.4.4, "SOURce:BB:MCCW Subsystem", on page 779.
Settings:
3.9.3.1 General Carrier Settings
Access:
Select "Baseband > Multi-Carrier CW".
Settings:
State............................................................................................................................242
Set to Default.............................................................................................................. 243
Number of Carriers......................................................................................................243
Carrier Spacing........................................................................................................... 243
Bandwidth................................................................................................................... 243
Clock Frequency......................................................................................................... 243
Optimize Crest Factor Mode....................................................................................... 243
Desired Crest Factor...................................................................................................244
State
Enables/disables the Multi-Carrier CW.
Switching on this option, turns off all the other digital standards and digital modulation
modes in the corresponding signal path.
Multi-carrier CW signals are computed in arbitrary waveform mode. To adopt the
changes in the settings of individual carriers, select "Accept". This selection applies to
the settings in the "Table Setup Assistant" section and the "Carrier Table" dialog.
Remote command:
[:SOURce<hw>]:BB:MCCW:STATe on page 784