EasyManua.ls Logo

Rohde & Schwarz SMBV100B - Output Settings

Rohde & Schwarz SMBV100B
1030 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Configuring the Internal Baseband Source
R&S
®
SMBV100B
231User Manual 1178.4460.02 ─ 03
"Peak"
The individual carriers are leveled based on their peak power and the
configured "Carrier Gain".
Example:
A multi carrier signal is composed from two waveform files.
First carrier "Gain" = 0 dB
Second carrier "Gain" = -3 dB
In the resulting multi carrier signal, the peak power of the second car-
rier signal will be 3 dB lower than the peak power of the first carrier
signal.
Example: Multi carrier signal composed of waveforms with dif-
ferent crest factor
A multi carrier signal is composed from two waveform files with the
following characteristics:
3GPP FDD signals with the same "Sample Rate" but different "Crest
Factors".
"Peak" = 0 dBFS
"Carrier Gain" = 0 dB
The Peak values of the carrier signals are equal, the RMS values are
different.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:MCARrier:POWer:REFerence on page 766
Output Settings
The output settings indicate the name, the file size, and the clock rate of the currently
calculated multi-carrier output file.
Generating Multi-Carrier Signals

Table of Contents