Multi-Instrument Setups
R&S
®
SMBV100B
459User Manual 1178.4460.02 ─ 03
"Digital I/Q In"
Estimates the sample rate based on the applied I/Q data clock and
displays the resulting value in the value field. The I/Q data clock sig-
nal is fed via the Dig I/Q input.
Note: Estimation works best if the sample rate is close to the user-
defined value.
"HS Digital I/Q In"
Estimates the sample rate value based on the information transmitted
by the transmitter.
Resulting value per channel is displayed by the parameter Sample
Rate.
Remote command:
[:SOURce<hw>]:BBIN:SRATe:SOURce on page 686
Connected Device
If the connection to the external device is properly established and signal transmission
is active, this parameter displays information on the instrument connected to the Dig
I/Q interface:
●
Name and serial number of the connected instrument
●
The transmitter sample rate, if supported by the transmitter
"None" indicates that no device is connected.
Remote command:
[:SOURce<hw>]:BBIN:CDEVice? on page 688
8.6.2 Signal Input Settings
Access:
1. Select "BB Input > Digital I/Q In > Baseband Input Settings > Interface = HS DIG
I/Q ".
2. Select "Signal Input".
Digital Baseband Input Settings