Remote Control Commands
R&S
®
SMBV100B
758User Manual 1178.4460.02 ─ 03
[:SOURce<hw>]:BB:ARBitrary:TRIGger:SMODe <SMode>
Selects the extended trigger mode for multi segment waveforms.
Parameters:
<SMode> SAME | NEXT | SEQuencer | NSEam
NSEam = Next Segment Seamless
*RST: NEXT
Example: See Example "Configuring the output order of the segments"
on page 741.
Manual operation: See "Next Segment Mode" on page 213
Multi-Segment Sequencing Commands
Required options
See Chapter 3.7.1, "Required Options", on page 193.
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:BLANk:APPend..............................758
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:CATalog?.......................................759
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:CLOCk.......................................... 759
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:CLOCk:MODE............................... 759
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:LEVel[:MODE]................................759
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:COMMent......................................760
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:DELete..........................................760
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:OFILe............................................760
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:SEGMent:APPend..........................760
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:SELect.......................................... 761
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:BLANk:APPend
<SampCount>, <Frequency>
Adds a blank segment to the multi-segment file.
Setting parameters:
<SampCount> float
Specifies the number of samples.
Range: 512 to 1E7
Increment: 1
*RST: 1000
<Frequency> float
Determines the clock rate.
Range: 400 Hz to depends on the installed options
Increment: 0.001
*RST: 1E8
Example: See Example "Creating a multi-segment waveform" on page 740
Usage: Setting only
SOURce Subsystem