Remote Control Commands
R&S
®
SMBV100B
773User Manual 1178.4460.02 ─ 03
Trigger Commands
[:SOURce<hw>]:BB:ARBitrary[:TRIGger]:SEQuence......................................................... 773
[:SOURce<hw>]:BB:ARBitrary:TRIGger:SOURce..............................................................773
[:SOURce<hw>]:BB:ARBitrary:TRIGger:RMODe?............................................................. 774
[:SOURce<hw>]:BB:ARBitrary:TRIGger:SLENgth..............................................................774
[:SOURce<hw>]:BB:ARBitrary:TRIGger:SLUNit................................................................ 774
[:SOURce<hw>]:BB:ARBitrary:TRIGger:ARM:EXECute..................................................... 774
[:SOURce<hw>]:BB:ARBitrary:TRIGger:EXECute............................................................. 775
[:SOURce<hw>]:BB:ARBitrary:TRIGger[:EXTernal]:SYNChronize:OUTPut...........................775
[:SOURce<hw>]:BB:ARBitrary:TRIGger:DELay:UNIT........................................................ 775
[:SOURce<hw>]:BB:ARBitrary:TRIGger[:EXTernal]:DELay................................................. 775
[:SOURce<hw>]:BB:ARBitrary:TRIGger[:EXTernal]:TDELay............................................... 776
[:SOURce<hw>]:BB:ARBitrary:TRIGger[:EXTernal]:RDELay?.............................................776
[:SOURce<hw>]:BB:ARBitrary:TRIGger[:EXTernal]:INHibit................................................. 776
[:SOURce<hw>]:BB:ARBitrary[:TRIGger]:SEQuence <Sequence>
The command selects the trigger mode.
Parameters:
<Sequence> AUTO | RETRigger | AAUTo | ARETrigger | SINGle
*RST: AUTO
Example: See Example "Managing waveform files" on page 738
Manual operation: See "Mode" on page 110
[:SOURce<hw>]:BB:ARBitrary:TRIGger:SOURce <Source>
Selects the trigger signal source and determines the way the triggering is executed.
Provided are:
Internal triggering by a command (INTernal)
External trigger signal via one of the User x connectors
EGT1: External global trigger
EGC1: External global clock
In master-slave mode, the external baseband synchronization signal (BBSY)
EXTernal: Setting only
Provided only for backward compatibility with other Rohde & Schwarz signal gener-
ators.
The R&S SMBV100B accepts this value and maps it automatically as follows:
EXTernal = EGT1
Parameters:
<Source> INTernal|EGT1|EGC1|EXTernal|BBSY
*RST: INTernal
Example: See Example "Managing waveform files" on page 738
Manual operation: See "Source" on page 111
SOURce Subsystem

Table of Contents

Related product manuals