Remote Control Commands
R&S
®
SMBV100B
853User Manual 1178.4460.02 ─ 03
// Export the list file data into the ASCII file
SOUR1:LIST:DEXC:EXEC
// Query the available ASCII files with extension .csv
SOUR1:LIST:DEXC:AFIL:CAT?
// Response: "list1ASCII"
// Deactivate the list mode
SOUR1:FREQ:MODE CW
● List Mode Settings.................................................................................................853
● List Mode File Operation.......................................................................................858
● List Mode Data Exchange.....................................................................................860
12.16.11.1 List Mode Settings
With the following commands, you can create list mode data, select the trigger mode
and determine the dwell time.
[:SOURce<hw>]:LIST:DWELl.......................................................................................... 853
[:SOURce<hw>]:LIST:DWELl:MODE................................................................................854
[:SOURce<hw>]:LIST:DWELl:LIST...................................................................................854
[:SOURce<hw>]:LIST:DWELl:LIST:POINts?......................................................................854
[:SOURce<hw>]:LIST:FREQuency...................................................................................855
[:SOURce<hw>]:LIST:FREQuency:POINts?......................................................................855
[:SOURce<hw>]:LIST:INDex............................................................................................855
[:SOURce<hw>]:LIST:INDex:STARt................................................................................. 856
[:SOURce<hw>]:LIST:INDex:STOP..................................................................................856
[:SOURce<hw>]:LIST:MODE...........................................................................................856
[:SOURce<hw>]:LIST:POWer..........................................................................................856
[:SOURce<hw>]:LIST:POWer:POINts?.............................................................................857
[:SOURce<hw>]:LIST:TRIGger:EXECute..........................................................................857
[:SOURce<hw>]:LIST:TRIGger:SOURce.......................................................................... 857
[:SOURce<hw>]:LIST:RUNNing?..................................................................................... 858
[:SOURce<hw>]:LIST:DWELl <Dwell>
Sets the global dwell time. The instrument generates the signal with the frequency /
power value pairs of each list entry for that particular period.
See also Significant Parameters and Functions.
Parameters:
<Dwell> float
Range: 1E-3 to 100
Increment: 1E-6
*RST: 0.01
Example: See Example "Create an RF list and activate the list mode"
on page 850.
Manual operation: See "Global Dwell Time" on page 337
SOURce Subsystem