Remote Control Commands
R&S
®
SMBV100B
664User Manual 1178.4460.02 ─ 03
Example: Configuring master-slave mode
// in the first (master) instrument
SOURce1:ROSCillator:SOURce INT
SCONfiguration:MULTiinstrument:MODe MAST
SCONfiguration:MULTiinstrument:STATe 1
SCONfiguration:APPLy
// in the second (slave) instrument
SOURce1:ROSCillator:SOURce EXT
SOURce1:ROSCillator:EXTernal:FREQuency 10MHZ
SCONfiguration:MULTiinstrument:MODe SLAV
SCONfiguration:MULTiinstrument:STATe 1
SOURce1:INPut:USER5:DIRection INP
SOURce1:INPut:USER4:SIGNal OUTSinc
SOURce1:INPut:USER5:DIRection OUTP
OUTPut1:USER5:SIGNal INSinc
SCONfiguration:MULTiinstrument:TRIGger:SYNChronization?
// SYNC
● Multi Instrument Configuration.............................................................................. 664
● I/Q Stream Mapping..............................................................................................665
● External RF and I/Q Instruments...........................................................................665
12.15.1 Multi Instrument Configuration
Commands:
:SCONfiguration:MULTiinstrument:MODE.........................................................................664
:SCONfiguration:MULTiinstrument:STATe......................................................................... 664
:SCONfiguration:MULTiinstrument:TRIGger:SYNChronization?...........................................665
:SCONfiguration:MULTiinstrument:MODE <MSMode>
Sets if the instrument works as master or as slave.
Parameters:
<MSMode> SLAVe | MASTer
*RST: MASTer
Example: See Example "Configuring master-slave mode" on page 664.
Manual operation: See "Multi Instrument Trigger" on page 430
:SCONfiguration:MULTiinstrument:STATe <TriggerState>
Activates the selected mode.
Parameters:
<TriggerState> 0 | 1 | OFF | ON
*RST: 0
SCONfiguration Subsystem