Configuring the RF Signal
R&S
®
SMBV100B
358User Manual 1178.4460.02 ─ 03
The "Pulse Generator" tab contains the settings for creating the pulse modulation
signal internally.
Pulse Generator > General Settings.....................................................................358
Pulse Generator > General Settings
Access:
Select "RF" > "Analog Modulation" > "Pulse Generator".
Settings
Pulse Mode................................................................................................................. 358
Trigger Mode...............................................................................................................359
Pulse Period................................................................................................................361
Pulse Width.................................................................................................................361
Double Pulse Width.....................................................................................................362
Pulse Delay.................................................................................................................362
Double Pulse Delay.....................................................................................................362
Pulse Output State......................................................................................................362
Show Connector..........................................................................................................362
Pulse Output Polarity.................................................................................................. 362
Execute Single Trigger................................................................................................362
Pulse Mode
Sets the operating mode of the pulse generator. Depending on the selection, the instru-
ment displays the associated parameters.
"Single"
Generates a single pulse in one pulse period.
"Double"
Generates two pulses in one pulse period.
Remote command:
[:SOURce<hw>]:PULM:MODE on page 705