Configuring the Internal Baseband Source
R&S
®
SMBV100B
111User Manual 1178.4460.02 ─ 03
Refer to "Impact of the Trigger Modes on the Signal Generation" on page 97 for a
detailed description of the provided trigger modes.
Remote command:
[:SOURce<hw>]:BB:DM[:TRIGger]:SEQuence on page 725
[:SOURce<hw>]:BB:ARBitrary[:TRIGger]:SEQuence on page 773
[:SOURce<hw>]:BB:MCCW[:TRIGger]:SEQuence on page 793
Signal Duration
Enters the length of the signal sequence to be output in the "Single" trigger mode.
Use this parameter to output part of the signal deliberately, an exact sequence of the
signal, or a defined number of repetitions of the signal.
Remote command:
[:SOURce<hw>]:BB:DM:TRIGger:SLENgth on page 726
[:SOURce<hw>]:BB:ARBitrary:TRIGger:SLUNit on page 774
[:SOURce<hw>]:BB:MCCW:TRIGger:SLENgth on page 791
Running/Stopped
With enabled modulation, displays the status of signal generation for all trigger modes.
●
"Running"
The signal is generated; a trigger was (internally or externally) initiated in triggered
mode.
●
"Stopped"
The signal is not generated and the instrument waits for a trigger event.
Remote command:
[:SOURce<hw>]:BB:DM:TRIGger:RMODe? on page 726
[:SOURce<hw>]:BB:ARBitrary:TRIGger:RMODe? on page 774
[:SOURce<hw>]:BB:MCCW:TRIGger:RMODe? on page 791
Arm
Stops the signal generation until subsequent trigger event occurs.
Remote command:
[:SOURce<hw>]:BB:DM:TRIGger:ARM:EXECute on page 726
[:SOURce<hw>]:BB:ARBitrary:TRIGger:ARM:EXECute on page 774
[:SOURce<hw>]:BB:MCCW:TRIGger:ARM:EXECute on page 790
Execute Trigger
For internal trigger source, executes trigger manually.
Remote command:
[:SOURce<hw>]:BB:DM:TRIGger:EXECute on page 727
[:SOURce<hw>]:BB:ARBitrary:TRIGger:EXECute on page 775
[:SOURce<hw>]:BB:MCCW:TRIGger:EXECute on page 791
Source
The following sources of the trigger signal are available:
●
"Internal"
The trigger event is executed manually by the "Execute Trigger".
●
"External Global Trigger"
Common Functions and Settings in the Baseband Domain