Remote Control Commands
R&S
®
SMBV100B
830User Manual 1178.4460.02 ─ 03
Manual operation: See "Impedance" on page 369
[:SOURce]:INPut:TRIGger:SLOPe <Slope>
Sets the polarity of the active slope of an applied instrument trigger.
Parameters:
<Slope> NEGative | POSitive
*RST: POSitive
Example:
INP:TRIG:SLOP NEG
Activates the falling slope of the external trigger signal at the
trigger input.
Manual operation: See "Trigger Slope" on page 331
12.16.8
SOURce:IQ Subsystem
The SOURce:IQ subsystem contains the commands for configuring the I/Q modula-
tion.
Required options
See Chapter 5.1, "Required Options", on page 277.
[:SOURce<hw>]:IQ:SOURce...........................................................................................830
[:SOURce<hw>]:IQ:STATe.............................................................................................. 831
[:SOURce<hw>]:IQ:GAIN................................................................................................831
[:SOURce<hw>]:BB:IQGain............................................................................................ 831
[:SOURce<hw>]:IQ:CREStfactor......................................................................................831
[:SOURce<hw>]:IQ:SWAP[:STATe].................................................................................. 831
[:SOURce<hw>]:IQ:WBSTate.......................................................................................... 832
[:SOURce<hw>]:IQ:SOURce <Source>
Selects the input signal source for the I/Q modulator.
Parameters:
<Source> BASeband | ANALog
External signals disable the amplitude modulation, an enabled
custom digital modulation, any configured digital standard or an
applied digital baseband input signal.
Example:
SOURce1:IQ:SOURce ANALog
Selects an external analog signal as the input signal. The signal
must be applied at the I and Q inputs.
Manual operation: See "Source" on page 279