Remote Control Commands
R&S
®
SMBV100B
753User Manual 1178.4460.02 ─ 03
[:SOURce<hw>]:BB:ARBitrary:CLOCk <Clock>
Sets the clock rate.
If you load a waveform, the clock rate is determined as defined with the waveform tag
{CLOCK: frequency}. This command subsequently changes the clock rate; see
data sheet for value range.
Parameters:
<Clock> float
Range: depends on the installed options
Increment: 0.001
*RST: 1E6
Default unit: Hz
E.g. 400 Hz to 600 MHz
Example: See Example "Managing waveform files" on page 738.
Manual operation: See "Clock Frequency" on page 153
[:SOURce<hw>]:BB:ARBitrary:WAVeform:CLOCk
<Filename>, <Clock>
Appends information on the ARB clock rate to specified waveform file. The file must
contain I/Q and/or marker data and have been created with the command :MMEMory:
DATA:UNPRotected on page 624.
Parameters:
<Filename> string
Complete file path and file name with file extension (*.wv).
If the file is in the default directory, the file path can be omitted.
Setting parameters:
<Clock> float
Range: 400 to 100E6
Increment: 1E-3
*RST: 1E6
Example: see :MMEMory:DATA:UNPRotected on page 624
Multi-Segment Commands
Required options
See Chapter 3.7.1, "Required Options", on page 193.
[:SOURce<hw>]:BB:ARBitrary:WSEGment?..................................................................... 754
[:SOURce<hw>]:BB:ARBitrary:WSEGment:NAME?...........................................................754
[:SOURce<hw>]:BB:ARBitrary:WSEGment:NEXT............................................................. 754
[:SOURce<hw>]:BB:ARBitrary:WSEGment:NEXT:EXECute............................................... 755
[:SOURce<hw>]:BB:ARBitrary:WSEGment:NEXT:SOURce................................................ 755
[:SOURce<hw>]:BB:ARBitrary:WSEGment:LMODe...........................................................755
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:SEGMent:CATalog?........................755