Remote Control Commands
R&S
®
SMBV100B
755User Manual 1178.4460.02 ─ 03
[:SOURce<hw>]:BB:ARBitrary:WSEGment:NEXT:EXECute
Triggers manually switchover to the subsequent segment in the multi-segment file.
This command is disabled, if a sequencing play list is enabled.
Example: See Example "Configuring the output order of the segments"
on page 741
Usage: Event
Manual operation: See "Execute Next Segment" on page 214
[:SOURce<hw>]:BB:ARBitrary:WSEGment:NEXT:SOURce <Source>
Selects the next segment source.
Parameters:
<Source> INTernal | NSEGM1
*RST: INTernal
Example: See Example "Configuring the output order of the segments"
on page 741.
Manual operation: See "Next Segment Source" on page 214
[:SOURce<hw>]:BB:ARBitrary:WSEGment:LMODe <LevelMode>
Sets how the segments are leveled.
Parameters:
<LevelMode> HIGHest | UNCHanged
*RST: HIGHest
Example:
:SOURce1:BB:ARBitrary:WSEGment:LMODe HIGHest
Manual operation: See "Level Mode" on page 214
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:SEGMent:CATalog?
Queries the segments of the currently selected configuration file.
Return values:
<Catalog> string
Example: See Example "Creating a multi-segment waveform"
on page 740.
Usage: Query only
Manual operation: See "Multi Segment Table" on page 203