759User Manual 1178.4460.02 ─ 03
Manual operation: See "Blank Segment" on page 204
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:CATalog?
Queries the available configuration files in the default directory. See also Chap-
ter 3.7.2.3, "File Concept", on page 194.
Return values:
<Catalog> string
Example: see Example "Creating a multi-segment waveform" on page 740
Usage: Query only
Manual operation: See "Load List" on page 201
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:CLOCk
<Clock>
Defines the clock rate used for multi-segment waveform output if the clock mode is
USER.
Parameters:
<Clock> float
Increment: 1E-3
*RST: max SampleRate
Example: See Example "Creating a multi-segment waveform" on page 740
Manual operation: See "User Clock Rate" on page 206
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:CLOCk:MODE <Mode>
Selects the clock rate mode for the multi segment waveform. Use the command [:
SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:CLOCk to define the clock
in clock mode user.
Parameters:
<Mode> UNCHanged | HIGHest | USER
*RST: UNCHanged
Example: See Example "Creating a multi-segment waveform"
on page 740.
Manual operation: See "Clock" on page 206
[:SOURce<hw>]:BB:ARBitrary:WSEGment:CONFigure:LEVel[:MODE] <Mode>
Selects the level mode, unchanged or equal RMS, for the multi-segment waveform.
Parameters:
<Mode> UNCHanged | ERMS
*RST: UNCHanged
SOURce Subsystem